Par and Spectrometer by Mammoth Lighting
Par and Spectrometer by Mammoth Lighting
Product Options
- 
              £49.95In Stock
Introducing our cutting-edge Par Meter and Spectrometer, a technological marvel crafted for precision and performance. Engineered with a high-speed CPU processor and a high-precision electronic CCD optical sensor, this device operates on the principle of long focal cross asymmetric CT spectroscopy system, delivering unparalleled accuracy and stability.
Key Features:
1. Advanced Optical Technology:
- Optical resolution of 2nm for precise measurements.
- Wider wavelength range ensures comprehensive analysis.
- Stable performance under various conditions.
2. Electronic Shutter Technology:
- Minimum integration time as low as 50us, allowing measurement of strong and weak optical signals.
- Adjustable integration time for versatility in signal detection.
3. Sleek and Portable Design:
- All-aluminum alloy precision carving for a lightweight and portable body.
- Modern design, completely discarding the bulk of traditional models.
4. Open Operating System:
- Upgraded system with a more open operating system and source code.
- Facilitates intelligent product applications and provides space for unlimited instrument upgrades.
5. Intuitive User Interface:
- 3.5-inch high-definition IPS capacitive touch screen for a vibrant display.
- High resolution for more content on a single screen, realistic graphics, and a smoother user experience.
- Thoughtful interface design enhances usability.
6. Quick and Convenient:
- Quick on/off functionality for swift operations.
- One-click testing for seamless measurements.
- Large battery capacity allows for 24 hours of extended testing time.
Whether you're a professional researcher, scientist, or enthusiast, our Par Meter and Spectrometer redefine the standards of accuracy, convenience, and portability. Elevate your experiments and measurements with a device designed for the future of scientific exploration.
B. Function Description:
- 
    PPFD PAR:
    - Measures Photosynthetic Photon Flux Density for optimal plant growth.
 
- Spectral Distribution Map:
    - Provides a detailed map of the spectral distribution for comprehensive analysis.
 
- Related Color Temperature Tc (K):
    - Offers color temperature information for accurate lighting assessment.
 
- Illuminance E (lx):
    - Measures the level of illuminance in lux for well-lit environments.
 
- Irradiance Ee (W/m²):
    - Determines irradiance for a complete understanding of light intensity.
 
- Chromaticity Coordinates (x, y):
    - Presents chromaticity coordinates for precise color representation.
 
- Relative Spectral Power Distribution P(λ):
    - Illustrates the relative distribution of spectral power.
 
- Color Rendering Index Ra, Ri (i=1-15):
    - Evaluates color rendering accuracy across a spectrum of indices.
 
- Color Rendering Index:
    - Measures the device's ability to reproduce colors accurately.
 
- Chromaticity Coordinate Map:
    - Displays a map of chromaticity coordinates for comprehensive analysis.
 
- Color Tolerance Map SDCM:
    - Illustrates color tolerance using Standard Deviation of Color Matching.
 
- Main Wavelength, Peak Wavelength, Half Width:
    - Provides crucial information about the light spectrum.
 
- Light to Dark Visual Ratio S/P:
    - Evaluates the visual experience by assessing light-to-dark ratios.
 
- Color Purity, Red Ratio, Green Ratio, Blue Ratio:
    - Analyzes color components to ensure accurate representation.
 
- Can Export Spectral Data per Nanometer:
    - Allows for detailed spectral data export for in-depth analysis.
 
- More Functional Parameters Can Be Customized:
    - Tailor the device to specific requirements with customizable parameters.
 
C. Main Technical Indicators:
- 
    Model and Name:
    - M400 Spectral Color Illuminometer.
 
- Wavelength Range:
    - 380nm~780nm for comprehensive spectral coverage.
 
- Split Mode:
    - Long focal cross asymmetric CT split beam system.
 
- Sensor:
    - High-precision CCD for accurate light sensing.
 
- Spectral Bandwidth (FWHM):
    - 2nm for detailed spectral analysis.
 
- Spectral Resolution:
    - 0.2nm for high-resolution data.
 
- x, Y Coordinate Value x, y Accuracy:
    - ±0.0015 accuracy; ±0.0005 repeatability.
 
- Wavelength Accuracy:
    - ±0.5nm for precise wavelength measurements.
 
- Wavelength Data Output Interval:
    - 1nm; EXCEL can export data corresponding to each nanometer.
 
- Illumination Accuracy Level:
    - Level 1 (±4% reading ±1 reading) for reliable results.
 
- Color Rendering Accuracy:
    - ±1.5% for accurate color representation.
 
- Photosensitive Surface:
    - Ф 10mm for efficient light capture.
 
- Screen Type:
    - 3.5-inch high-definition IPS capacitive touch screen for intuitive operation.
 
- Chromaticity Standard Accuracy:
    - ±0.0025, traceable to NIM for reliable color temperature assessments.
 
- Color Temperature Range:
    - 1000K~100000K for versatile lighting conditions.
 
- Stray Light:
    - ≤0.3% to minimize interference.
 
- Illuminance Measurement Range:
    - 0.1Lux~2000Klux for diverse lighting environments.
 
- Measurement Mode:
    - Single test/continuous test for flexibility in testing scenarios.
 
Please note: Wand sold separately. 
Tags: Par, Meter, Spectrometer
Q & A
Be the first to ask a question.

 










 
    








